Review measurement

2026-09-13 18:20

Ozone Enzo 3 XL (2017)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
7744
rdg:
7737
diff:
 -7
A16
nom:
7718
rdg:
7709
diff:
 -9
B24
nom:
7752
rdg:
7757
diff:
 +5
B25
nom:
7751
rdg:
7753
diff:
 +2

Right riser

A15
nom:
7744
rdg:
7732
diff:
-12
A16
nom:
7718
rdg:
7708
diff:
-10
B24
nom:
7752
rdg:
7754
diff:
 +2
B25
nom:
7751
rdg:
7755
diff:
 +4

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7961.17
rdg:
7973.33
diff:
12.17
nom:
8014.29
rdg:
8013.00
diff:
-1.29

Right riser

nom:
8678.25
rdg:
8691.50
diff:
13.25
nom:
8707.83
rdg:
8709.42
diff:
1.58
nom:
7961.17
rdg:
7966.83
diff:
5.67
nom:
8014.29
rdg:
8009.86
diff:
-4.43

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (5) of the deviations of all measurements from their nominal values.

No issues were found