Review measurement
2025-03-14 17:50
Nova Codex XS (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
SAG1
nom:
6361
rdg:
6390
diff:
+29
SAG2
nom:
6325
rdg:
6355
diff:
+30
SG1
nom:
6296
rdg:
6324
diff:
+28
SBG1
nom:
6361
rdg:
6386
diff:
+25
SBG2
nom:
6326
rdg:
6351
diff:
+25
SG2
nom:
6309
rdg:
6339
diff:
+30
SCG1
nom:
6388
rdg:
6413
diff:
+25
SCG2
nom:
6354
rdg:
6376
diff:
+22
SG3
nom:
6334
rdg:
6357
diff:
+23
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found