Review measurement
2024-11-27 20:52
Ozone Rush 6 MS (2021)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6820
rdg:
6914
diff:
+94
A10
nom:
6763
rdg:
6859
diff:
+96
A11
nom:
6674
rdg:
6776
diff:
+102
A12
nom:
6662
rdg:
6761
diff:
+99
A13
nom:
6565
rdg:
6666
diff:
+101
A14
nom:
6571
rdg:
6670
diff:
+99
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7138.25
rdg:
7237.25
diff:
+99.00
nom:
7054.50
rdg:
7155.50
diff:
+101.00
nom:
7243.63
rdg:
7354.75
diff:
+111.13
nom:
6675.83
rdg:
6775.33
diff:
+99.50
nom:
6669.67
rdg:
6779.50
diff:
+109.83
Right riser
nom:
7138.25
rdg:
7240.75
diff:
+102.50
nom:
7054.50
rdg:
7157.50
diff:
+103.00
nom:
7243.63
rdg:
7358.75
diff:
+115.13
nom:
6953.25
rdg:
7063.00
diff:
+109.75
nom:
6892.00
rdg:
6995.00
diff:
+103.00
nom:
7070.50
rdg:
7186.88
diff:
+116.38
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found