Review measurement

2024-04-15 19:47

Ozone Zeolite 2 GT MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6837
rdg:
6823
diff:
-14
A10
nom:
6709
rdg:
6700
diff:
 -9
A11
nom:
6640
rdg:
6626
diff:
-14
A12
nom:
6545
rdg:
6540
diff:
 -5
A13
nom:
6525
rdg:
6519
diff:
 -6
B12
nom:
6566
rdg:
6558
diff:
 -8
B13
nom:
6549
rdg:
6544
diff:
 -5

Right riser

A9
nom:
6837
rdg:
6821
diff:
-16
A10
nom:
6709
rdg:
6700
diff:
 -9
A11
nom:
6640
rdg:
6627
diff:
-13
A12
nom:
6545
rdg:
6540
diff:
 -5
A13
nom:
6525
rdg:
6518
diff:
 -7
B12
nom:
6566
rdg:
6562
diff:
 -4
B13
nom:
6549
rdg:
6544
diff:
 -5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7313.63
rdg:
7287.00
diff:
-26.63
nom:
7314.13
rdg:
7302.38
diff:
-11.75

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-17) of the deviations of all measurements from their nominal values.

No issues were found