Review measurement
2024-04-15 19:47
Ozone Zeolite 2 GT MS (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
6837
rdg:
6821
diff:
-16
A10
nom:
6709
rdg:
6700
diff:
-9
A11
nom:
6640
rdg:
6627
diff:
-13
A12
nom:
6545
rdg:
6540
diff:
-5
A13
nom:
6525
rdg:
6518
diff:
-7
B12
nom:
6566
rdg:
6562
diff:
-4
B13
nom:
6549
rdg:
6544
diff:
-5
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7313.63
rdg:
7287.00
diff:
-26.63
nom:
7314.13
rdg:
7302.38
diff:
-11.75
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found