Review measurement

2025-10-27 18:31

Nova Ion 4 S (2016)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

Ag8
nom:
6526
rdg:
6508
diff:
-18
Sg1
nom:
6276
rdg:
6246
diff:
-30
Bg8
nom:
6546
rdg:
6521
diff:
-25
Sg2
nom:
6297
rdg:
6265
diff:
-32
Sg3
nom:
6372
rdg:
6344
diff:
-28
Sg4
nom:
6459
rdg:
6427
diff:
-32

Right riser

Ag8
nom:
6526
rdg:
6505
diff:
-21
Sg1
nom:
6276
rdg:
6244
diff:
-32
Bg8
nom:
6546
rdg:
6523
diff:
-23
Sg2
nom:
6297
rdg:
6264
diff:
-33
Sg3
nom:
6372
rdg:
6339
diff:
-33
Sg4
nom:
6459
rdg:
6429
diff:
-30

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found