Review measurement

2026-05-03 16:05

Ozone Alpina 4 ML (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5
nom:
7279
rdg:
7206
diff:
-73
A6
nom:
7245
rdg:
7173
diff:
-72
A7
nom:
7182
rdg:
7111
diff:
-71
A8
nom:
7183
rdg:
7110
diff:
-73

Right riser

A5
nom:
7279
rdg:
7208
diff:
-71
A6
nom:
7245
rdg:
7177
diff:
-68
A7
nom:
7182
rdg:
7122
diff:
-60
A8
nom:
7183
rdg:
7121
diff:
-62

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7222.25
rdg:
7150.00
diff:
-72.25
nom:
7170.00
rdg:
7108.50
diff:
-61.50
nom:
7323.60
rdg:
7259.20
diff:
-64.40

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-68) of the deviations of all measurements from their nominal values.

No issues were found