Review measurement
2025-05-14 12:43
Ozone Zeno 2 ML (2022)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A5a
        nom:
7697
rdg:
7703
diff:
 +6
A6a
        nom:
7538
rdg:
7542
diff:
 +4
A7a
        nom:
7461
rdg:
7464
diff:
 +3
A8a
        nom:
7488
rdg:
7490
diff:
 +2
A5b
        nom:
7687
rdg:
7690
diff:
 +3
A6b
        nom:
7529
rdg:
7530
diff:
 +1
A7b
        nom:
7456
rdg:
7456
diff:
 +0
A8b
        nom:
7486
rdg:
7483
diff:
 -3
Right riser
A9
        nom:
7238
rdg:
7236
diff:
 -2
A10
        nom:
7112
rdg:
7108
diff:
 -4
A11
        nom:
7043
rdg:
7041
diff:
 -2
A12
        nom:
6996
rdg:
6992
diff:
 -4
A13
        nom:
6976
rdg:
6970
diff:
 -6
A14
        nom:
7018
rdg:
7010
diff:
 -8
B12
        nom:
7005
rdg:
6999
diff:
 -6
B13
        nom:
7013
rdg:
7007
diff:
 -6
B14
        nom:
7041
rdg:
7032
diff:
 -9
A5a
        nom:
7697
rdg:
7707
diff:
+10
A6a
        nom:
7538
rdg:
7543
diff:
 +5
A7a
        nom:
7461
rdg:
7468
diff:
 +7
A8a
        nom:
7488
rdg:
7490
diff:
 +2
A5b
        nom:
7687
rdg:
7695
diff:
 +8
A6b
        nom:
7529
rdg:
7530
diff:
 +1
A7b
        nom:
7456
rdg:
7459
diff:
 +3
A8b
        nom:
7486
rdg:
7483
diff:
 -3
Trim
                            Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
                                Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
                            
No issues were found