Review measurement

2026-02-13 01:09

Ozone Mantra M6 MS (2014)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
6232
rdg:
6728
diff:
-34
A16
nom:
6092
rdg:
6587
diff:
-35
B15
nom:
6203
rdg:
6694
diff:
-39
B16
nom:
6111
rdg:
6609
diff:
-32

Right riser

A15
nom:
6232
rdg:
6727
diff:
-35
A16
nom:
6092
rdg:
6586
diff:
-36
B15
nom:
6203
rdg:
6690
diff:
-43
B16
nom:
6111
rdg:
6609
diff:
-32

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7593.25
rdg:
7577.00
diff:
-16.25
nom:
7509.50
rdg:
7485.00
diff:
-24.50
nom:
7616.33
rdg:
7588.50
diff:
-27.83
nom:
7408.75
rdg:
7397.00
diff:
-11.75
nom:
7337.25
rdg:
7314.75
diff:
-22.50
nom:
7440.00
rdg:
7415.17
diff:
-24.83
nom:
7110.67
rdg:
7097.17
diff:
-13.50
nom:
7058.33
rdg:
7026.83
diff:
-31.50
nom:
7094.33
rdg:
7064.33
diff:
-30.00

Right riser

nom:
7110.67
rdg:
7082.17
diff:
-28.50
nom:
7058.33
rdg:
7021.67
diff:
-36.67
nom:
7094.33
rdg:
7068.33
diff:
-26.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found