Review measurement

2025-03-23 14:34

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6992
rdg:
6994
diff:
2.00
A10
nom:
6871
rdg:
6878
diff:
7.00
A11
nom:
6806
rdg:
6812
diff:
6.00
A12
nom:
6761
rdg:
6767
diff:
6.00
A13
nom:
6742
rdg:
6748
diff:
6.00
A14
nom:
6782
rdg:
6784
diff:
2.00
B12
nom:
6769
rdg:
6775
diff:
6.00
B13
nom:
6778
rdg:
6784
diff:
6.00
B14
nom:
6805
rdg:
6808
diff:
3.00

Right riser

A9
nom:
6992
rdg:
7001
diff:
9.00
A10
nom:
6871
rdg:
6884
diff:
13.00
A11
nom:
6806
rdg:
6818
diff:
12.00
A12
nom:
6761
rdg:
6769
diff:
8.00
A13
nom:
6742
rdg:
6749
diff:
7.00
A14
nom:
6782
rdg:
6783
diff:
1.00
B12
nom:
6769
rdg:
6776
diff:
7.00
B13
nom:
6778
rdg:
6787
diff:
9.00
B14
nom:
6805
rdg:
6806
diff:
1.00

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found