Review measurement

2024-06-15 12:51

Ozone Zeno 2 ML (2022)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
5.50
std dev:
1.93
A1a
dev:
-2.5
A2a
dev:
+0.5
A3a
dev:
-2.5
A4a
dev:
-0.5
A1b
dev:
+2.5
A2b
dev:
-0.5
A3b
dev:
+0.5
A4b
dev:
+2.5
avg change:
4.75
std dev:
1.91
A5a
dev:
-1.3
A6a
dev:
-0.3
A7a
dev:
+0.8
A8a
dev:
+1.8
A5b
dev:
-1.3
A6b
dev:
+2.8
A7b
dev:
-3.3
A8b
dev:
+0.8

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
7661
rdg:
7653
diff:
 -8
B6
nom:
7519
rdg:
7512
diff:
 -7
B7
nom:
7441
rdg:
7433
diff:
 -8
B8
nom:
7451
rdg:
7443
diff:
 -8
C5
nom:
7738
rdg:
7732
diff:
 -6
C6
nom:
7595
rdg:
7593
diff:
 -2
C7
nom:
7512
rdg:
7510
diff:
 -2
C8
nom:
7512
rdg:
7505
diff:
 -7

Right riser

B5
nom:
7661
rdg:
7648
diff:
-13
B6
nom:
7519
rdg:
7510
diff:
 -9
B7
nom:
7441
rdg:
7432
diff:
 -9
B8
nom:
7451
rdg:
7443
diff:
 -8
C5
nom:
7738
rdg:
7733
diff:
 -5
C6
nom:
7595
rdg:
7592
diff:
 -3
C7
nom:
7512
rdg:
7510
diff:
 -2
C8
nom:
7512
rdg:
7506
diff:
 -6

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee