Review measurement

2024-06-15 12:51

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B5
nom:
7661
rdg:
7653
diff:
-8
B6
nom:
7519
rdg:
7512
diff:
-7
B7
nom:
7441
rdg:
7433
diff:
-8
B8
nom:
7451
rdg:
7443
diff:
-8
C5
nom:
7738
rdg:
7732
diff:
-6
C6
nom:
7595
rdg:
7593
diff:
-2
C7
nom:
7512
rdg:
7510
diff:
-2
C8
nom:
7512
rdg:
7505
diff:
-7

Right riser

B5
nom:
7661
rdg:
7648
diff:
-13
B6
nom:
7519
rdg:
7510
diff:
-9
B7
nom:
7441
rdg:
7432
diff:
-9
B8
nom:
7451
rdg:
7443
diff:
-8
C5
nom:
7738
rdg:
7733
diff:
-5
C6
nom:
7595
rdg:
7592
diff:
-3
C7
nom:
7512
rdg:
7510
diff:
-2
C8
nom:
7512
rdg:
7506
diff:
-6

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found