Review measurement

2025-06-18 18:02

Ozone Photon L (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7553
rdg:
7569
diff:
+16
A6a
nom:
7407
rdg:
7414
diff:
 +7
A7a
nom:
7332
rdg:
7338
diff:
 +6
A8a
nom:
7343
rdg:
7351
diff:
 +8
A5b
nom:
7540
rdg:
7553
diff:
+13
A6b
nom:
7396
rdg:
7406
diff:
+10
A7b
nom:
7323
rdg:
7332
diff:
 +9
A8b
nom:
7338
rdg:
7346
diff:
 +8

Right riser

A5a
nom:
7553
rdg:
7567
diff:
+14
A6a
nom:
7407
rdg:
7416
diff:
 +9
A7a
nom:
7332
rdg:
7346
diff:
+14
A8a
nom:
7343
rdg:
7353
diff:
+10
A5b
nom:
7540
rdg:
7556
diff:
+16
A6b
nom:
7396
rdg:
7406
diff:
+10
A7b
nom:
7323
rdg:
7337
diff:
+14
A8b
nom:
7338
rdg:
7343
diff:
 +5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7646.25
rdg:
7657.25
diff:
11.00
nom:
7665.75
rdg:
7691.13
diff:
25.38
nom:
7038.00
rdg:
7045.33
diff:
7.33
nom:
7058.33
rdg:
7078.67
diff:
20.33

Right riser

nom:
7646.25
rdg:
7656.88
diff:
10.63
nom:
7665.75
rdg:
7689.75
diff:
24.00

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found