Review measurement

2024-03-27 14:34

Ozone Enzo 3 M (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
8099
rdg:
7914
diff:
-185
A6a
nom:
7952
rdg:
7773
diff:
-179
A7a
nom:
7881
rdg:
7704
diff:
-177
A8a
nom:
7909
rdg:
7732
diff:
-177
A5b
nom:
8082
rdg:
7903
diff:
-179
A6b
nom:
7936
rdg:
7759
diff:
-177
A7b
nom:
7866
rdg:
7694
diff:
-172
A8b
nom:
7897
rdg:
7722
diff:
-175

Right riser

A5a
nom:
8099
rdg:
7919
diff:
-180
A6a
nom:
7952
rdg:
7771
diff:
-181
A7a
nom:
7881
rdg:
7706
diff:
-175
A8a
nom:
7909
rdg:
7731
diff:
-178
A5b
nom:
8082
rdg:
7903
diff:
-179
A6b
nom:
7936
rdg:
7758
diff:
-178
A7b
nom:
7866
rdg:
7693
diff:
-173
A8b
nom:
7897
rdg:
7722
diff:
-175

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us a