Review measurement

2026-04-08 16:01

AirDesign Volt 5 M (2024)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A13
nom:
7065
rdg:
7072
diff:
 +7
A14
nom:
6952
rdg:
6966
diff:
+14
A15
nom:
6932
rdg:
6943
diff:
+11
B13
nom:
7023
rdg:
7032
diff:
 +9
B14
nom:
6950
rdg:
6963
diff:
+13
B15
nom:
6940
rdg:
6951
diff:
+11
C13
nom:
6978
rdg:
6986
diff:
 +8
C14
nom:
7001
rdg:
7012
diff:
+11

Right riser

A13
nom:
7065
rdg:
7076
diff:
+11
A14
nom:
6952
rdg:
6968
diff:
+16
A15
nom:
6932
rdg:
6943
diff:
+11
B13
nom:
7023
rdg:
7030
diff:
 +7
B14
nom:
6950
rdg:
6959
diff:
 +9
B15
nom:
6940
rdg:
6950
diff:
+10
C13
nom:
6978
rdg:
6986
diff:
 +8
C14
nom:
7001
rdg:
7006
diff:
 +5

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7773.75
rdg:
7798.25
diff:
24.50
nom:
7824.42
rdg:
7836.42
diff:
12.00

Right riser

nom:
7773.75
rdg:
7801.75
diff:
28.00
nom:
7824.42
rdg:
7836.83
diff:
12.42

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found