Review measurement
2024-06-23 15:56
Ozone Photon L (2023)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A5a
nom:
7553
rdg:
7582
diff:
+29
A6a
nom:
7407
rdg:
7441
diff:
+34
A7a
nom:
7332
rdg:
7363
diff:
+31
A8a
nom:
7343
rdg:
7372
diff:
+29
A5b
nom:
7540
rdg:
7571
diff:
+31
A6b
nom:
7396
rdg:
7431
diff:
+35
A7b
nom:
7323
rdg:
7356
diff:
+33
A8b
nom:
7338
rdg:
7370
diff:
+32
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
7038.00
rdg:
7083.67
diff:
+45.67
nom:
7058.33
rdg:
7087.00
diff:
+28.67
Right riser
nom:
7038.00
rdg:
7078.00
diff:
+40.00
nom:
7058.33
rdg:
7087.67
diff:
+29.33
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found