Review measurement
2023-07-24 21:39
Ozone Zeno 2 ML (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
A1a
nom:
7921
rdg:
7921
diff:
+0
A2a
nom:
7810
rdg:
7810
diff:
+0
A3a
nom:
7771
rdg:
7768
diff:
-3
A4a
nom:
7805
rdg:
7802
diff:
-3
A1b
nom:
7906
rdg:
7901
diff:
-5
A2b
nom:
7795
rdg:
7789
diff:
-6
A3b
nom:
7758
rdg:
7751
diff:
-7
A4b
nom:
7793
rdg:
7787
diff:
-6
Right riser
A9
nom:
7238
rdg:
7230
diff:
-8
A10
nom:
7112
rdg:
7103
diff:
-9
A11
nom:
7043
rdg:
7038
diff:
-5
A12
nom:
6996
rdg:
6988
diff:
-8
A13
nom:
6976
rdg:
6971
diff:
-5
A14
nom:
7018
rdg:
7010
diff:
-8
B12
nom:
7005
rdg:
6995
diff:
-10
B13
nom:
7013
rdg:
7001
diff:
-12
B14
nom:
7041
rdg:
7025
diff:
-16
A1a
nom:
7921
rdg:
7927
diff:
+6
A2a
nom:
7810
rdg:
7807
diff:
-3
A3a
nom:
7771
rdg:
7766
diff:
-5
A4a
nom:
7805
rdg:
7802
diff:
-3
A1b
nom:
7906
rdg:
7903
diff:
-3
A2b
nom:
7795
rdg:
7789
diff:
-6
A3b
nom:
7758
rdg:
7756
diff:
-2
A4b
nom:
7793
rdg:
7790
diff:
-3
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found