Review measurement

2024-10-15 11:47

Ozone Alpina 4 S (2020)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6621
rdg:
6581
diff:
-40
A10
nom:
6581
rdg:
6543
diff:
-38
A11
nom:
6505
rdg:
6470
diff:
-35
A12
nom:
6492
rdg:
6457
diff:
-35
A13
nom:
6410
rdg:
6381
diff:
-29
A14
nom:
6413
rdg:
6384
diff:
-29

Right riser

A9
nom:
6621
rdg:
6577
diff:
-44
A10
nom:
6581
rdg:
6540
diff:
-41
A11
nom:
6505
rdg:
6467
diff:
-38
A12
nom:
6492
rdg:
6455
diff:
-37
A13
nom:
6410
rdg:
6379
diff:
-31
A14
nom:
6413
rdg:
6382
diff:
-31

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found