Review measurement

2025-10-26 10:55

Ozone Zeolite 2 GT MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6837
rdg:
6828
diff:
 -9
A10
nom:
6709
rdg:
6706
diff:
 -3
A11
nom:
6640
rdg:
6635
diff:
 -5
A12
nom:
6545
rdg:
6548
diff:
 +3
A13
nom:
6525
rdg:
6517
diff:
 -8
B12
nom:
6566
rdg:
6566
diff:
 +0
B13
nom:
6549
rdg:
6545
diff:
 -4

Right riser

A9
nom:
6837
rdg:
6846
diff:
 +9
A10
nom:
6709
rdg:
6717
diff:
 +8
A11
nom:
6640
rdg:
6645
diff:
 +5
A12
nom:
6545
rdg:
6553
diff:
 +8
A13
nom:
6525
rdg:
6528
diff:
 +3
B12
nom:
6566
rdg:
6572
diff:
 +6
B13
nom:
6549
rdg:
6551
diff:
 +2

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found