Review measurement
2025-06-13 01:39
Ozone Photon MS (2023)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A1a
nom:
7258
rdg:
7245
diff:
-13
A2a
nom:
7157
rdg:
7141
diff:
-16
A3a
nom:
7121
rdg:
7101
diff:
-20
A4a
nom:
7153
rdg:
7135
diff:
-18
A1b
nom:
7243
rdg:
7229
diff:
-14
A2b
nom:
7141
rdg:
7125
diff:
-16
A3b
nom:
7107
rdg:
7090
diff:
-17
A4b
nom:
7140
rdg:
7126
diff:
-14
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found