Review measurement

2026-10-07 17:29

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6992
rdg:
6981
diff:
-11
A10
nom:
6871
rdg:
6861
diff:
-10
A11
nom:
6806
rdg:
6796
diff:
-10
A12
nom:
6761
rdg:
6744
diff:
-17
A13
nom:
6742
rdg:
6725
diff:
-17
A14
nom:
6782
rdg:
6760
diff:
-22
B12
nom:
6769
rdg:
6751
diff:
-18
B13
nom:
6778
rdg:
6761
diff:
-17
B14
nom:
6805
rdg:
6783
diff:
-22

Right riser

A9
nom:
6992
rdg:
6985
diff:
 -7
A10
nom:
6871
rdg:
6864
diff:
 -7
A11
nom:
6806
rdg:
6800
diff:
 -6
A12
nom:
6761
rdg:
6747
diff:
-14
A13
nom:
6742
rdg:
6729
diff:
-13
A14
nom:
6782
rdg:
6769
diff:
-13
B12
nom:
6769
rdg:
6754
diff:
-15
B13
nom:
6778
rdg:
6766
diff:
-12
B14
nom:
6805
rdg:
6790
diff:
-15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-7) of the deviations of all measurements from their nominal values.

No issues were found