Review measurement

2026-02-21 20:13

Ozone Alpina 4 S (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6621
rdg:
6571
diff:
-50
A10
nom:
6581
rdg:
6537
diff:
-44
A11
nom:
6505
rdg:
6460
diff:
-45
A12
nom:
6492
rdg:
6448
diff:
-44
A13
nom:
6410
rdg:
6373
diff:
-37
A14
nom:
6413
rdg:
6374
diff:
-39

Right riser

A9
nom:
6621
rdg:
6573
diff:
-48
A10
nom:
6581
rdg:
6533
diff:
-48
A11
nom:
6505
rdg:
6463
diff:
-42
A12
nom:
6492
rdg:
6449
diff:
-43
A13
nom:
6410
rdg:
6369
diff:
-41
A14
nom:
6413
rdg:
6373
diff:
-40

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6808.50
rdg:
6767.25
diff:
-41.25
nom:
6756.00
rdg:
6715.50
diff:
-40.50
nom:
6905.80
rdg:
6874.80
diff:
-31.00
nom:
6503.67
rdg:
6460.00
diff:
-43.67
nom:
6565.23
rdg:
6532.46
diff:
-32.77

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-37) of the deviations of all measurements from their nominal values.

No issues were found