Review measurement

2026-02-21 20:13

Ozone Alpina 4 S (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6621
rdg:
6571
diff:
-50
A10
nom:
6581
rdg:
6537
diff:
-44
A11
nom:
6505
rdg:
6460
diff:
-45
A12
nom:
6492
rdg:
6448
diff:
-44
A13
nom:
6410
rdg:
6373
diff:
-37
A14
nom:
6413
rdg:
6374
diff:
-39

Right riser

A9
nom:
6621
rdg:
6573
diff:
-48
A10
nom:
6581
rdg:
6533
diff:
-48
A11
nom:
6505
rdg:
6463
diff:
-42
A12
nom:
6492
rdg:
6449
diff:
-43
A13
nom:
6410
rdg:
6369
diff:
-41
A14
nom:
6413
rdg:
6373
diff:
-40

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

Right riser

nom:
6808.50
rdg:
6767.25
diff:
-41.25
nom:
6756.00
rdg:
6715.50
diff:
-40.50
nom:
6905.80
rdg:
6874.80
diff:
-31.00
nom:
6503.67
rdg:
6460.00
diff:
-43.67
nom:
6565.23
rdg:
6532.46
diff:
-32.77

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found