Review measurement

2026-05-17 13:20

Ozone Photon ML (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A5a
nom:
7324
rdg:
7347
diff:
+23
A6a
nom:
7184
rdg:
7203
diff:
+19
A7a
nom:
7112
rdg:
7130
diff:
+18
A8a
nom:
7123
rdg:
7140
diff:
+17
A5b
nom:
7313
rdg:
7338
diff:
+25
A6b
nom:
7173
rdg:
7194
diff:
+21
A7b
nom:
7104
rdg:
7122
diff:
+18
A8b
nom:
7118
rdg:
7132
diff:
+14

Right riser

A5a
nom:
7324
rdg:
7346
diff:
+22
A6a
nom:
7184
rdg:
7202
diff:
+18
A7a
nom:
7112
rdg:
7129
diff:
+17
A8a
nom:
7123
rdg:
7138
diff:
+15
A5b
nom:
7313
rdg:
7338
diff:
+25
A6b
nom:
7173
rdg:
7193
diff:
+20
A7b
nom:
7104
rdg:
7124
diff:
+20
A8b
nom:
7118
rdg:
7133
diff:
+15

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found