Review measurement

2026-07-11 09:03

Ozone Zeolite 2 GT MS (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6837
rdg:
6830
diff:
 -7
A10
nom:
6709
rdg:
6707
diff:
 -2
A11
nom:
6640
rdg:
6633
diff:
 -7
A12
nom:
6545
rdg:
6537
diff:
 -8
A13
nom:
6525
rdg:
6511
diff:
-14
B12
nom:
6566
rdg:
6556
diff:
-10
B13
nom:
6549
rdg:
6535
diff:
-14

Right riser

A9
nom:
6837
rdg:
6828
diff:
 -9
A10
nom:
6709
rdg:
6708
diff:
 -1
A11
nom:
6640
rdg:
6634
diff:
 -6
A12
nom:
6545
rdg:
6532
diff:
-13
A13
nom:
6525
rdg:
6512
diff:
-13
B12
nom:
6566
rdg:
6550
diff:
-16
B13
nom:
6549
rdg:
6536
diff:
-13

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7313.63
rdg:
7309.25
diff:
-4.38
nom:
7314.13
rdg:
7297.50
diff:
-16.63

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-11) of the deviations of all measurements from their nominal values.

No issues were found