Review measurement
2026-05-04 15:16
AirDesign Eazy XS (2013)
In-group deviations
Readings that are more than 10
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
C1
nom:
6235
rdg:
6648
diff:
-67
C2
nom:
6195
rdg:
6611
diff:
-64
C3
nom:
6180
rdg:
6594
diff:
-66
C4
nom:
6220
rdg:
6635
diff:
-65
D1
nom:
6335
rdg:
6741
diff:
-74
D2
nom:
6245
rdg:
6659
diff:
-66
D3
nom:
6290
rdg:
6703
diff:
-67
D4
nom:
6280
rdg:
6691
diff:
-69
D5
nom:
6270
rdg:
6684
diff:
-66
D6
nom:
6385
rdg:
6796
diff:
-69
E1
nom:
6405
rdg:
6811
diff:
-74
E2
nom:
6325
rdg:
6735
diff:
-70
E3
nom:
6365
rdg:
6773
diff:
-72
E4
nom:
6355
rdg:
6761
diff:
-74
E5
nom:
6345
rdg:
6755
diff:
-70
E6
nom:
6440
rdg:
6851
diff:
-69
Trim
Groups arranged behind each other in flight direction having more than 10
No issues were found
Group deviations
Groups that are more than 20
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found