Review measurement

2025-12-14 12:48

Ozone Zeno 2 ML (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
7238
rdg:
7234
diff:
 -4
A10
nom:
7112
rdg:
7114
diff:
 +2
A11
nom:
7043
rdg:
7048
diff:
 +5
A12
nom:
6996
rdg:
7008
diff:
+12
A13
nom:
6976
rdg:
6983
diff:
 +7
A14
nom:
7018
rdg:
7028
diff:
+10
B12
nom:
7005
rdg:
7012
diff:
 +7
B13
nom:
7013
rdg:
7021
diff:
 +8
B14
nom:
7041
rdg:
7052
diff:
+11

Right riser

A9
nom:
7238
rdg:
7233
diff:
 -5
A10
nom:
7112
rdg:
7112
diff:
 +0
A11
nom:
7043
rdg:
7049
diff:
 +6
A12
nom:
6996
rdg:
7006
diff:
+10
A13
nom:
6976
rdg:
6985
diff:
 +9
A14
nom:
7018
rdg:
7026
diff:
 +8
B12
nom:
7005
rdg:
7016
diff:
+11
B13
nom:
7013
rdg:
7021
diff:
 +8
B14
nom:
7041
rdg:
7052
diff:
+11

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found