Review measurement

2024-02-26 21:24

Ozone Enzo 3 S (2017)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A15
nom:
7083
rdg:
7095
diff:
+12
A16
nom:
7059
rdg:
7068
diff:
+9
B24
nom:
7089
rdg:
7103
diff:
+14
B25
nom:
7088
rdg:
7103
diff:
+15

Right riser

A15
nom:
7083
rdg:
7087
diff:
+4
A16
nom:
7059
rdg:
7066
diff:
+7
B24
nom:
7089
rdg:
7105
diff:
+16
B25
nom:
7088
rdg:
7101
diff:
+13

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found