Review measurement

2026-03-12 14:06

Ozone Alpina 5 L (2025)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B7
nom:
7356
rdg:
7349
diff:
 -7
B8
nom:
7250
rdg:
7246
diff:
 -4
B9
nom:
7226
rdg:
7219
diff:
 -7
B10
nom:
7156
rdg:
7146
diff:
-10
B11
nom:
7137
rdg:
7128
diff:
 -9
B12
nom:
7149
rdg:
7141
diff:
 -8
C7
nom:
7451
rdg:
7451
diff:
 +0
C8
nom:
7341
rdg:
7345
diff:
 +4
C9
nom:
7314
rdg:
7317
diff:
 +3
C10
nom:
7236
rdg:
7236
diff:
 +0
C11
nom:
7215
rdg:
7213
diff:
 -2
C12
nom:
7207
rdg:
7204
diff:
 -3

Right riser

B7
nom:
7356
rdg:
7340
diff:
-16
B8
nom:
7250
rdg:
7239
diff:
-11
B9
nom:
7226
rdg:
7214
diff:
-12
B10
nom:
7156
rdg:
7142
diff:
-14
B11
nom:
7137
rdg:
7127
diff:
-10
B12
nom:
7149
rdg:
7134
diff:
-15
C7
nom:
7451
rdg:
7443
diff:
 -8
C8
nom:
7341
rdg:
7334
diff:
 -7
C9
nom:
7314
rdg:
7308
diff:
 -6
C10
nom:
7236
rdg:
7230
diff:
 -6
C11
nom:
7215
rdg:
7210
diff:
 -5
C12
nom:
7207
rdg:
7200
diff:
 -7

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found