Review measurement

2026-06-02 02:14

Ozone Zeolite 2 GT S (2023)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A9
nom:
6585
rdg:
6549
diff:
-36
A10
nom:
6463
rdg:
6429
diff:
-34
A11
nom:
6397
rdg:
6361
diff:
-36
A12
nom:
6307
rdg:
6268
diff:
-39
A13
nom:
6288
rdg:
6245
diff:
-43
B12
nom:
6327
rdg:
6289
diff:
-38
B13
nom:
6310
rdg:
6269
diff:
-41

Right riser

A9
nom:
6585
rdg:
6552
diff:
-33
A10
nom:
6463
rdg:
6432
diff:
-31
A11
nom:
6397
rdg:
6365
diff:
-32
A12
nom:
6307
rdg:
6271
diff:
-36
A13
nom:
6288
rdg:
6249
diff:
-39
B12
nom:
6327
rdg:
6286
diff:
-41
B13
nom:
6310
rdg:
6266
diff:
-44

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.