Review measurement

2026-01-08 18:35

Ozone Enzo 3 S (2017)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
8.43
std dev:
3.21
B17
dev:
-4.6
B18
dev:
-0.6
B19
dev:
-1.6
B20
dev:
-1.6
B21
dev:
+5.4
B22
dev:
+2.4
B23
dev:
+0.4

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B17
nom:
7433
rdg:
7401
diff:
-32
B18
nom:
7372
rdg:
7337
diff:
-35
B19
nom:
7354
rdg:
7321
diff:
-33
B20
nom:
7283
rdg:
7247
diff:
-36
B21
nom:
7286
rdg:
7256
diff:
-30
B22
nom:
7243
rdg:
7202
diff:
-41
B23
nom:
7251
rdg:
7211
diff:
-40

Right riser

B17
nom:
7433
rdg:
7395
diff:
-38
B18
nom:
7372
rdg:
7332
diff:
-40
B19
nom:
7354
rdg:
7317
diff:
-37
B20
nom:
7283
rdg:
7245
diff:
-38
B21
nom:
7286
rdg:
7250
diff:
-36
B22
nom:
7243
rdg:
7199
diff:
-44
B23
nom:
7251
rdg:
7209
diff:
-42

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found