Review measurement
2025-02-04 21:45
BGD Diva 2 M (2024)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
a9
nom:
6664
rdg:
6688
diff:
+24
a10
nom:
6637
rdg:
6664
diff:
+27
a11
nom:
6577
rdg:
6601
diff:
+24
a12
nom:
6571
rdg:
6595
diff:
+24
a13
nom:
6499
rdg:
6526
diff:
+27
a14
nom:
6499
rdg:
6522
diff:
+23
a15
nom:
6460
rdg:
6483
diff:
+23
a16
nom:
6456
rdg:
6478
diff:
+22
a17
nom:
6463
rdg:
6481
diff:
+18
c15
nom:
6499
rdg:
6517
diff:
+18
c16
nom:
6507
rdg:
6526
diff:
+19
c17
nom:
6540
rdg:
6559
diff:
+19
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
This should be corrected.
Left riser
nom:
6574.50
rdg:
6603.67
diff:
+29.17
nom:
6555.50
rdg:
6569.50
diff:
+14.00
Right riser
nom:
6574.50
rdg:
6599.33
diff:
+24.83
nom:
6555.50
rdg:
6567.50
diff:
+12.00
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found