Review measurement

2025-11-02 20:25

Supair Savage M (2020)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

c9
nom:
7543
rdg:
7561
diff:
+18
c10
nom:
7490
rdg:
7508
diff:
+18
c11
nom:
7421
rdg:
7440
diff:
+19
c12
nom:
7383
rdg:
7395
diff:
+12

Right riser

c9
nom:
7543
rdg:
7561
diff:
+18
c10
nom:
7490
rdg:
7506
diff:
+16
c11
nom:
7421
rdg:
7436
diff:
+15
c12
nom:
7383
rdg:
7390
diff:
 +7

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

This should be corrected.

Left riser

nom:
7059.33
rdg:
7053.00
diff:
-27.33

Right riser

nom:
7059.33
rdg:
7050.17
diff:
-30.17

Buy us coffee