Review measurement

2025-11-09 09:57

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7651
rdg:
7662
diff:
+11
A2a
nom:
7543
rdg:
7549
diff:
 +6
A3a
nom:
7506
rdg:
7512
diff:
 +6
A4a
nom:
7539
rdg:
7547
diff:
 +8
A1b
nom:
7636
rdg:
7646
diff:
+10
A2b
nom:
7528
rdg:
7530
diff:
 +2
A3b
nom:
7492
rdg:
7492
diff:
 +0
A4b
nom:
7526
rdg:
7531
diff:
 +5

Right riser

A1a
nom:
7651
rdg:
7666
diff:
+15
A2a
nom:
7543
rdg:
7552
diff:
 +9
A3a
nom:
7506
rdg:
7515
diff:
 +9
A4a
nom:
7539
rdg:
7547
diff:
 +8
A1b
nom:
7636
rdg:
7647
diff:
+11
A2b
nom:
7528
rdg:
7534
diff:
 +6
A3b
nom:
7492
rdg:
7497
diff:
 +5
A4b
nom:
7526
rdg:
7532
diff:
 +6

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7552.63
rdg:
7558.63
diff:
6.00
nom:
7561.63
rdg:
7556.00
diff:
-5.63

Right riser

nom:
7552.63
rdg:
7561.25
diff:
8.63
nom:
7561.63
rdg:
7556.50
diff:
-5.13

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found

Buy us coffee