Review measurement

2025-11-09 09:57

Ozone Zeno 2 MS (2022)

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A1a
nom:
7651
rdg:
7662
diff:
+11
A2a
nom:
7543
rdg:
7549
diff:
 +6
A3a
nom:
7506
rdg:
7512
diff:
 +6
A4a
nom:
7539
rdg:
7547
diff:
 +8
A1b
nom:
7636
rdg:
7646
diff:
+10
A2b
nom:
7528
rdg:
7530
diff:
 +2
A3b
nom:
7492
rdg:
7492
diff:
 +0
A4b
nom:
7526
rdg:
7531
diff:
 +5

Right riser

A1a
nom:
7651
rdg:
7666
diff:
+15
A2a
nom:
7543
rdg:
7552
diff:
 +9
A3a
nom:
7506
rdg:
7515
diff:
 +9
A4a
nom:
7539
rdg:
7547
diff:
 +8
A1b
nom:
7636
rdg:
7647
diff:
+11
A2b
nom:
7528
rdg:
7534
diff:
 +6
A3b
nom:
7492
rdg:
7497
diff:
 +5
A4b
nom:
7526
rdg:
7532
diff:
 +6

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

This should be corrected.

Left riser

nom:
7552.63
rdg:
7558.63
diff:
6.00
nom:
7561.63
rdg:
7556.00
diff:
-5.63

Right riser

nom:
7552.63
rdg:
7561.25
diff:
8.63
nom:
7561.63
rdg:
7556.50
diff:
-5.13

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-1) of the deviations of all measurements from their nominal values.

No issues were found