Review measurement

2026-09-12 17:35

Ozone Alpina 4 GT S (2025)

Accuracy

Is calculated by comparing each suspension point's length change to the main line's overall change after re-measurement. Deviations over 3.0mm from the average are considered noticeable and may distort the trim result.

Left riser

avg change:
17.25
std dev:
2.36
A1
dev:
+0.3
A2
dev:
-1.8
A3
dev:
+3.3
A4
dev:
-1.8
avg change:
3.15
std dev:
4.16
B9
dev:
+0.2
B10
dev:
+2.2
B11
dev:
+5.2
B12
dev:
+8.2
B13
dev:
+2.2
B14
dev:
+0.2
B15
dev:
+0.2
C13
dev:
-0.8
C14
dev:
-1.8
C15
dev:
-2.8
C16
dev:
-3.8
C17
dev:
-8.8
C18
dev:
+0.2
avg change:
6.50
std dev:
2.32
C1
dev:
-4.5
C2
dev:
-2.5
C3
dev:
-0.5
C4
dev:
+2.5
C5
dev:
+3.5
C6
dev:
+0.5
D1
dev:
+0.5
D2
dev:
-0.5
D3
dev:
+1.5
D4
dev:
-0.5

Right riser

In-group deviations

Readings that are more than 10mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

B9
nom:
6696
rdg:
6685
diff:
-11
B10
nom:
6610
rdg:
6606
diff:
 -4
B11
nom:
6611
rdg:
6612
diff:
 +1
B12
nom:
6518
rdg:
6520
diff:
 +2
B13
nom:
6509
rdg:
6511
diff:
 +2
B14
nom:
6423
rdg:
6422
diff:
 -1
B15
nom:
6426
rdg:
6423
diff:
 -3
C13
nom:
6762
rdg:
6752
diff:
-10
C14
nom:
6676
rdg:
6668
diff:
 -8
C15
nom:
6584
rdg:
6582
diff:
 -2
C16
nom:
6567
rdg:
6564
diff:
 -3
C17
nom:
6487
rdg:
6481
diff:
 -6
C18
nom:
6479
rdg:
6474
diff:
 -5

Right riser

B9
nom:
6696
rdg:
6689
diff:
 -7
B10
nom:
6610
rdg:
6608
diff:
 -2
B11
nom:
6611
rdg:
6607
diff:
 -4
B12
nom:
6518
rdg:
6515
diff:
 -3
B13
nom:
6509
rdg:
6508
diff:
 -1
B14
nom:
6423
rdg:
6418
diff:
 -5
B15
nom:
6426
rdg:
6427
diff:
 +1
C13
nom:
6762
rdg:
6757
diff:
 -5
C14
nom:
6676
rdg:
6671
diff:
 -5
C15
nom:
6584
rdg:
6586
diff:
 +2
C16
nom:
6567
rdg:
6567
diff:
 +0
C17
nom:
6487
rdg:
6488
diff:
 +1
C18
nom:
6479
rdg:
6477
diff:
 -2

Trim

Groups arranged behind each other in flight direction having more than 10mm deviation.

No issues were found

Group deviations

Groups that are more than 20mm away from measurement baseline.
The measurement baseline is the median (-3) of the deviations of all measurements from their nominal values.

No issues were found