Review measurement
2024-07-14 04:41
Ozone Buzz Z5 ML (2015)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
C9
nom:
6390
rdg:
6900
diff:
+10
C10
nom:
6344
rdg:
6852
diff:
+8
C11
nom:
6253
rdg:
6761
diff:
+8
C12
nom:
6215
rdg:
6720
diff:
+5
D9
nom:
6456
rdg:
6953
diff:
-3
D10
nom:
6404
rdg:
6906
diff:
+2
D11
nom:
6305
rdg:
6807
diff:
+2
D12
nom:
6263
rdg:
6765
diff:
+2
Right riser
C1
nom:
6637
rdg:
7132
diff:
-5
C2
nom:
6591
rdg:
7086
diff:
-5
C3
nom:
6566
rdg:
7066
diff:
+0
C4
nom:
6575
rdg:
7079
diff:
+4
D1
nom:
6742
rdg:
7241
diff:
-1
D2
nom:
6695
rdg:
7193
diff:
-2
D3
nom:
6667
rdg:
7166
diff:
-1
D4
nom:
6674
rdg:
7177
diff:
+3
C9
nom:
6390
rdg:
6894
diff:
+4
C10
nom:
6344
rdg:
6851
diff:
+7
C11
nom:
6253
rdg:
6756
diff:
+3
C12
nom:
6215
rdg:
6723
diff:
+8
D9
nom:
6456
rdg:
6955
diff:
-1
D10
nom:
6404
rdg:
6905
diff:
+1
D11
nom:
6305
rdg:
6806
diff:
+1
D12
nom:
6263
rdg:
6770
diff:
+7
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found