Review measurement
2024-06-16 01:15
Ozone Zeno 2 L (2022)
In-group deviations
Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.
Left riser
Right riser
A9
nom:
7585
rdg:
7590
diff:
+5
A10
nom:
7451
rdg:
7461
diff:
+10
A11
nom:
7379
rdg:
7386
diff:
+7
A12
nom:
7335
rdg:
7331
diff:
-4
A13
nom:
7314
rdg:
7310
diff:
-4
A14
nom:
7357
rdg:
7350
diff:
-7
B12
nom:
7344
rdg:
7340
diff:
-4
B13
nom:
7352
rdg:
7348
diff:
-4
B14
nom:
7382
rdg:
7374
diff:
-8
Trim
Groups arranged behind each other in flight direction having more than 10 mm deviation.
No issues were found
Group deviations
Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.
No issues were found