Review measurement

2024-09-27 02:13

AirDesign Volt 4 ML (2022)

In-group deviations

Readings that are more than 10 mm away from each other within one group.
This could be a sign of inaccurate measuring setup/technique or swapped line map points.

Left riser

A13
nom:
7440
rdg:
7408
diff:
-32
A14
nom:
7323
rdg:
7299
diff:
-24
A15
nom:
7303
rdg:
7275
diff:
-28
B13
nom:
7402
rdg:
7384
diff:
-18
B14
nom:
7323
rdg:
7303
diff:
-20
B15
nom:
7314
rdg:
7296
diff:
-18
C15
nom:
7438
rdg:
7416
diff:
-22
C16
nom:
7356
rdg:
7338
diff:
-18
C17
nom:
7384
rdg:
7359
diff:
-25

Right riser

A13
nom:
7440
rdg:
7410
diff:
-30
A14
nom:
7323
rdg:
7303
diff:
-20
A15
nom:
7303
rdg:
7279
diff:
-24
B13
nom:
7402
rdg:
7381
diff:
-21
B14
nom:
7323
rdg:
7304
diff:
-19
B15
nom:
7314
rdg:
7295
diff:
-19
C15
nom:
7438
rdg:
7415
diff:
-23
C16
nom:
7356
rdg:
7335
diff:
-21
C17
nom:
7384
rdg:
7365
diff:
-19

Trim

Groups arranged behind each other in flight direction having more than 10 mm deviation.

No issues were found

Group deviations

Groups that are more than 20 mm away from measurement baseline.
The measurement baseline is the median of the deviations of all measurements from their nominal values.

No issues were found